Environmentally friendly screen-printed electrodes for the selective detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in forensic analysis.

Anne Alves Macedo, Dilton Martins Pimentel, Larissa Magalhães de Almeida Melo, Cláudia M Rocha, Ângelo de Fátima, Karla A O Souza, Jose L Costa, Luciano Chaves Arantes, Wallans Torres Pio Dos Santos

Analytical methods : advancing methods and applications November 14, 2024 DOI: 10.1039/d4ay01310g via PubMed

Summary

AI-generated from the abstract

Discarded screen-printed electrodes can be recoated with a graphite and chitosan mixture to create a reusable sensor for detecting the recreational drug 2C-B in oral fluid and seized samples. The sensor, called SPE-Gr/CTS, detects 2C-B electrochemically with a linear range from 0.05 to 7.5 μmol L⁻¹ and a detection limit of 0.015 μmol L⁻¹. Responses are stable across different electrodes, with relative standard deviation below 5.0%. The method is selective for 2C-B even when seventeen other illicit drugs or adulterants are present. Real seized and oral fluid samples were analyzed, and results matched those from LC-MS. The device offers a rapid, portable, and environmentally friendly screening tool for forensic analysis, using only 50 μL of sample.

Study at a glance

Characteristics Experimental study Peer reviewed
Keywords Forensic science Forensic analysis Drug detection Illicit drug identification Chemical forensics
Citations 6
Key finding Recoating discarded screen-printed electrodes with graphite and chitosan creates a reusable sensor that selectively detects 2C-B in oral fluid and seized samples with high sensitivity and stability.

Abstract

In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable SPE (SPE-Gr/CTS). Demonstrating its utility, SPE-Gr/CTS was employed for the detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B), a phenylethylamine commonly used for recreational proposes. Identifying 2C-B in fluid oral and seized samples is of great interest for forensic and toxicological applications. The 2C-B detection using SPE-Gr/CTS was optimized in Britton-Robinson buffer solution (0.1 mol L-1) at pH 2.0, employing square-wave adsorptive stripping voltammetry. The electrochemical behavior of 2C-B on SPE-Gr/CTS exhibited one irreversible oxidation and a reversible redox process. The proposed method presented a dynamic linear range for 2C-B determination (0.05 to 7.5 μmol L-1) with a low LOD (0.015 μmol L-1). Moreover, the stability of 2C-B electrochemical responses on SPE-Gr/CTS was confirmed using the same or different electrodes (N = 3), with a relative standard deviation of less than 5.0%. Interference studies with seventeen other illicit drugs and adulterants demonstrated that the proposed method is selective for 2C-B detection even in the presence of these substances. Real seized and oral fluid samples containing 2C-B were analyzed using this method, and the results were confirmed by LC-MS. The proposed device demonstrates to be an environmentally friendly and selective sensor for 2C-B detection in forensic analysis, offering a rapid and straightforward screening method for seized and biological samples. In addition, a portable and sensitive determination of 2C-B in forensic samples is presented with minimal sample consumption (50 μL).