Skip to content

A highly sensitive UHPLC-MS/MS method for determining 15 designer LSD analogs in biological samples with application to stability studies.

Olga Wachełko, Karolina Nowak, Kaja Tusiewicz, Marcin Zawadzki, Paweł Szpot

The Analyst January 13, 2025 DOI: 10.1039/d4an01361a via PubMed

Summary

AI-generated from the abstract

A highly sensitive analytical method using UHPLC-QqQ-MS/MS can detect LSD, 13 of its designer analogs, and a metabolite at femtogram-per-milliliter levels in blood, urine, plasma, and serum. The method separates structural isomers and achieves a limit of quantification of 0.5 pg/mL for all substances. A 30-day stability study showed that collecting samples in sodium fluoride (NaF) tubes stabilizes LSD analogs and minimizes conversion of N1-substituted compounds to LSD or MiPLA. The method is the most sensitive reported for analyzing designer LSD analogs in biological samples and is suitable for routine clinical and forensic use. Fragmentation patterns from mass spectra are proposed to aid future identification of new designer LSD analogs.

Study at a glance

Characteristics Method development and validation Peer reviewed
Duration 30 days (stability study)
Keywords Psychedelics Forensics Drug detection Analytical chemistry
Citations 4
Key finding The developed UHPLC-QqQ-MS/MS method is the most sensitive to date for trace detection of LSD and its designer analogs in biological samples, with NaF collection stabilizing the compounds and preventing conversion.

Abstract

In recent years, the rise in the synthesis and distribution of LSD analogs in illicit drug markets, commonly referred to as "designer psychedelics", has contributed to increased recreational use. This trend has resulted in a rising number of global reports, with law enforcement increasingly detecting these compounds in blotter papers and biological samples. In the presented paper, an UHPLC-QqQ-MS/MS method was developed for trace determination (fg mL-1) of LSD, its designer analogs (ALD-52, AL-LAD, LAMPA, LSM-775, LSZ, MiPLA, 1B-LSD, 1cP-LSD, 1cP-MiPLA, 1P-LSD, 1P-MiPLA, 1V-LSD and 2-Bromo-LSD) and its metabolite (2-oxo-3-OH-LSD) with simultaneous separation of structural isomers. Biological samples were prepared using liquid-liquid extraction (LLE) at pH 9 (with ethyl acetate); quantification was performed in multiple reaction monitoring (MRM) mode. LSD-d3 was used as an internal standard. The limit of quantification (LOQ) for all substances was 0.5 pg mL-1. Precision and accuracy did not exceed 15.8% and ±14.4%, respectively. Recovery and matrix effect values were 80.6-118.6% and ±19.4%. A stability study was conducted over 30 days under different storage conditions (25 °C, 4 °C and -20 °C) for blood, urine, plasma, and serum, collected in various test tube configurations and with different preservative agents. It was found that the collection of samples in NaF can effectively stabilize LSD analogs and minimize the conversion of N1-substituted compounds to LSD or MiPLA. The presented method is the most sensitive to date for analyzing designer LSD analogs in biological samples, with potential for routine clinical and forensic use, enhancing detection of emerging illicit compounds. By examining the mass spectra (QTOF-MS/MS) obtained in this study and reviewing the literature on analytical characterization of LSD analogs, we proposed fragmentation patterns to aid in future identification of new designer LSD analogs (NPS).

Comments

No comments yet.

Log in to comment