Evaluating Complexity of Fetal MEG Signals: A Comparison of Different Metrics and Their Applicability.
Julia Moser, Siouar Bensaid, Eleni Kroupi, Franziska Schleger, Fabrice Wendling, Giulio Ruffini, Hubert Preissl
Frontiers in systems neuroscience January 1, 2019 DOI: 10.3389/fnsys.2019.00023 via PubMed
Summary
AI-generated from the abstractInformation-based metrics of neural activity can help quantify consciousness before and shortly after birth. Using fetal magnetoencephalography (fMEG) in human fetuses and neonates, researchers evaluated measures of entropy, compressibility, and fractality. Lempel-Ziv-Complexity (LZC) was the most practical metric because it is unequivocal and requires low computational effort, whereas fractality and entropy measures need more parameter adjustments. Comparing a brain-activity channel with a control channel in neonates showed significant differences in most complexity metrics, serving as proof of concept. For fetal data, results were less clear, possibly due to leftover maternal signals. The inconsistency across metrics highlights challenges in using complexity metrics as neural correlates of consciousness.
Study at a glance
| Characteristics | Observational study Peer reviewed |
|---|---|
| Population | Human fetuses and neonates |
| Keywords | Lzc Complexity Entropy Fmeg Fractality |
| Key finding | Lempel-Ziv-Complexity (LZC) was the most usable metric for fMEG data, and comparison of a brain channel with a control channel in neonates showed significant differences in most complexity metrics. |
Abstract
In this work, we aim to investigate whether information based metrics of neural activity are a useful tool for the quantification of consciousness before and shortly after birth. Neural activity is measured using fetal magnetoencephalography (fMEG) in human fetuses and neonates. Based on recent theories on consciousness, information-based metrics are established to measure brain complexity and to assess different levels of consciousness. Different metrics (measures of entropy, compressibility and fractality) are, thus, explored in a reference population and their usability is evaluated. For comparative analysis, two fMEG channels were selected: one where brain activity was previously detected and one at least 15 cm away, that represented a control channel. The usability of each metric was evaluated and results from the brain and control channel were compared. Concerning the ease of use with fMEG data, Lempel-Ziv-Complexity (LZC) was evaluated as best, as it is unequivocal and needs low computational effort. The fractality measures have a high number of parameters that need to be adjusted prior to analysis and therefore forfeit comparability, while entropy measures require a higher computational effort and more parameters to adjust compared to LZC. Comparison of a channel with brain activity and a control channel in neonatal recordings showed significant differences in most complexity metrics. This clear difference can be seen as proof of concept for the usability of complexity metrics in fMEG. For fetal data, this comparison produced less clear results which can be related to leftover maternal signals included in the control channel. Further work is necessary to conclusively interpret results from the analysis of fetal recordings. Yet this study shows that complexity metrics can be used for fMEG data on early consciousness and the evaluation gives a guidance for future work. The inconsistency of results from different metrics highlights the challenges of working with complexity metrics as neural correlates of consciousness, as well as the caution one should apply to interpret them.