Skip to content

Investigation of Ayahuasca β-Carboline Alkaloids and Tryptamine in Sweat Samples from Religious Community Participants by GC-MS

Lidiane Silva Tavares, Fernanda Monedeiro, Dayanne Mozaner Bordin, Bruno Spinosa de Martinis

Journal of Analytical Toxicology January 21, 2020 DOI: 10.1093/jat/bkz116 via OpenAlex

Summary

AI-generated from the abstract

Sweat can be used to detect the main active components of ayahuasca—harmine, harmaline, and N,N-dimethyltryptamine (DMT)—during religious rituals. A solid-phase extraction method under basic conditions showed high selectivity and extraction efficiency above 70%, with accuracy between 87.5 and 102.4% and precision below 10%. Detection limits were 15 ng/patch for harmine and harmaline and 10 ng/patch for DMT. Sweat offers a non-invasive, simple collection alternative that does not disrupt rituals, making it a viable matrix for monitoring ayahuasca use.

Study at a glance

Characteristics Method development and validation study Peer reviewed
Population Ayahuasca users during a religious ritual
Topics Ayahuasca
Keywords Tryptamine Sweat Chemistry Gas chromatography–mass spectrometry
Citations 15
Key finding Sweat is a viable non-invasive matrix for detecting harmine, harmaline, and DMT in ayahuasca users during religious rituals.

Abstract

Abstract Ayahuasca, a hallucinogenic beverage used in religious rituals in South America, has become a global phenomenon. Its main active components are the β-carbolines alkaloids, harmine (HRM) and harmaline (HRL), as well as the potent hallucinogen N,N-dimethyltryptamine (DMT). Despite its rising consumption, information regarding possible clinical applications and toxicological effects of ayahuasca is still limited. This study presents the first investigation of the use of sweat for the determination of DMT, HRM and HRL in ayahuasca users during a religious ritual. Sweat is an alternative matrix with advantages over many conventional biological samples, mainly because the collection procedure is non-invasive, easy and simple and samples can be collected without disturbing the religious ritual. In the study, solid-phase extraction was performed under basic conditions. Linearity was observed ranging from 20 to 1500 ng/patch with coefficients of determination (R2) higher than 0.99 for all analytes. The results indicated high selectivity for all investigated analytes, with extraction efficiency exceeding 70%, accuracy ranging from 87.5 to 102.4%, intra-assay precision of 1.85–9.44% and inter-assay precision between 3.34 and 9.85%. The limits of detection were 15 ng/patch for HRM and HRL and 10 ng/patch for DMT. The sweat proved to be a viable option to monitor ayahuasca use.

Explore topics

Comments

No comments yet.

Log in to comment